DEFINITION
(For cross-wound package)
Cone-tapper angle or semi-vertical angle
- The angle between the side of the cone and its axis.
- Cone
tapper generally range between
Wind (single Traverse)
The number of coil laid on package in single traverse. A to C is one windTraverse Ratio
The number of coil laid on the package during
double traverse of the same wing point. Yarn laying from A to C is complete one
single traverse but from C to E complete a double traverse that is known as
traverse ratio.
Coil Angle
To angle between directions of yarn laid on the
package and plane perpendicular to axis. This angle is known as coil angle.
Crossing Angle
The angle at which
yarn coil cross each other. Crossing angle is twice of coli angle.
Approaches of building a cross wound package
- Build with constant traverse ratio
- Build with constant coil angle
REF: - fundamentals of yarn winding
by Milind Koranne (Woodhead Publishing India in textile)